This reference design generates a 5V/60A output from a standard 48V telecom input. Two UCC2891controllers are configured to control two interleaved active-clamp forward power stages. The secondary circuitry implements self-driven synchronous rectifiers for a highly efficient design. This design includes trimming: remote sense: and output overvoltage features.
Title | Updated | Type | Size (KB) |
---|---|---|---|
Design of a 60-A interleaved active-clamp forward converter | 22 Jan 2013 | 192 |
Download the bill of materials for PMP2214 | Download |
Title | Updated | Type | Size (KB) | |
---|---|---|---|---|
PMP2214 Gerber | 12 Oct 2012 | ZIP | 241 | |
PMP2214 PCB | 12 Oct 2012 | 299 | ||
PMP2214 BOM | 12 Oct 2012 | 21 | ||
PMP2214 Schematic | 12 Oct 2012 | 163 |