The PMP30082 reference design shows two stage power supply. The first stage is a fly-buck topology that converts an input of 48V-72V to a primary output voltage of 12V with a maximum load current of 250mA and to an isolated secondary output voltage of 24V with a load current of 160mA. Two Buck converters are connected to the primary 12V rail. One generates 5V with 400mA load current: the other one generates 3.3V with 100mA load current.
Download the bill of materials for PMP30082 | Download |
Get results faster with test and simulation data that's been verified.
Download the test file for PMP30082Title | Updated | Type | Size (KB) | |
---|---|---|---|---|
PMP30082 Gerber | 08 Aug 2016 | ZIP | 33 | |
PMP30082 CAD Files | 08 Aug 2016 | ZIP | 470 | |
PMP30082 PCB | 08 Aug 2016 | 169 | ||
PMP30082 Assembly Drawing | 08 Aug 2016 | 101 | ||
PMP30082 BOM | 08 Aug 2016 | 125 | ||
PMP30082 Schematic | 08 Aug 2016 | 313 |