This reference design provides a three-phase inverter rated up to 10 kW designed using the reinforced isolated gate driver UCC21530: reinforced isolated amplifiers AMC1301 and AMC1311 and MCU TMS320F28027. Lower system cost is achieved by using the AMC1301 to measure motor current interfaced with internal ADC of MCU and use of bootstrap power supply for IGBT gate drivers. The inverter is designed to have protection against overload: short circuit: ground fault: DC bus undervoltage and overvoltage: and IGBT module over temperature.
Download the bill of materials for TIDA-00366 | Download |
Get results faster with test and simulation data that's been verified.
Download the test file for TIDA-00366Title | Updated | Type | Size (KB) | |
---|---|---|---|---|
TIDA-00366 Schematic | 08 Jun 2016 | 1533 | ||
TIDA-00366 PCB | 08 Jun 2016 | 5537 | ||
TIDA-00366 Gerber | 08 Jun 2016 | ZIP | 1934 | |
TIDA-00366 CAD Files | 08 Jun 2016 | ZIP | 2737 | |
TIDA-00366 BOM | 08 Jun 2016 | 59 | ||