This referene design detects ground fault in inverter-based drives. Inverter current is measured on both DC-positive and DC-negative bus using shunt resistors. Current on DC-positive bus is measured using INA170 which is powered by a low-side switched buck converter. Current on DC-negative bus is sensed using precision op amps. The difference between the two measured currents is compared against a fixed threshold to determine the ground-fault condition using high-speed comparators.
Download the bill of materials for TIDA-00442 | Download |
Get results faster with test and simulation data that's been verified.
Download the test file for TIDA-00442Title | Updated | Type | Size (KB) | |
---|---|---|---|---|
TIDA-00442 Gerber | 19 Jun 2015 | ZIP | 375 | |
TIDA-00442 CAD Files | 19 Jun 2015 | ZIP | 1257 | |
TIDA-00442 PCB | 19 Jun 2015 | 1481 | ||
TIDA-00442 Assembly Drawing | 19 Jun 2015 | 162 | ||
TIDA-00442 BOM | 19 Jun 2015 | 38 | ||
TIDA-00442 Schematic | 19 Jun 2015 | 477 |