TIPD118 Reference Design

Texas Instruments

Bandpass-filtered -40-dB attenuator: less than 0.1-dB error reference design

Description

This TI Verified Design is a -40dB band-pass filtered inverting attenuator. The circuit creates a filtered: inverted: and attenuated output from a single-ended input signal that can be used for test and measurement: or other waveform generation applications. A single low-noise OPA1611 op amp is used to invert: attenuate: and filter the input signal. The low-noise and low-distortion performance of the OPA1611 allows for a very accurate and clean output signals.See more TI Precision Designs

Features
  • -40dB Filtered signal output0.1dB Flatband AccuracyLow-Noise output from OPA1611This verified design includes:TheoryComponent SelectionTINA-TI SimulationSchematics and PCB LayoutVerification and Measured PerformanceModification Options
Applications
Product Categories
  • Amplifiers

Parts

Part Number Name Companion Part
OPA1611 OPA1611 Buy Datasheet

Bill Of Materials

Download the bill of materials for TIPD118 Download

Schematic

Quickly understand overall system functionality.

Download the schematic for TIPD118

Test Data

Get results faster with test and simulation data that's been verified.

Download the test file for TIPD118

Other Documents

Title Updated Type Size (KB)
TIPD118 Gerber 20 Sep 2013 ZIP 289
TIPD118 BOM 20 Sep 2013 PDF 72
TIPD118 Schematic 20 Sep 2013 PDF 123