This circuit consists of a single-supply op amp configured as a transimpedance amplifier with a bandwidth greater than 1MHz for amplifying the light- dependent current of a photodiode. A small bias voltage derived from the positive supply and applied to the op amp’s non-inverting input. This prevents the output from saturating at the negative supply rail in the absence of input current. It is designed to produce output voltages of .1V to 4.9V for photodiode currents of 0uA to 90uA. This circuit is designed for use in common transimpedance amplifier applications such as barcode scanners: optical networking: and spectrometers.
Application Area | End Equipment |
---|---|
Blood glucose monitor | https://www.ti.com/solution/blood-glucose-monitor#referencedesigns |
Download |
---|
Download the bill of materials for TIPD176 | Download |
Get results faster with test and simulation data that's been verified.
Download the test file for TIPD176Title | Updated | Type | Size (KB) | |
---|---|---|---|---|
TIPD176 BOM | 21 Nov 2014 | 72 | ||
TIPD176 Schematic | 21 Nov 2014 | 105 |