TIPD188 Reference Design

Texas Instruments

High-Resolution: Low-Drift: Precision Weigh-Scale Reference Design with AC Bridge Excitation

Description

This precision weigh-scale reference design achieves greater than 50:000 noise-free counts of resolution. Offset and offset drift errors are nearly eliminated by ac bridge excitation. This design takes advantage of the high-resolution ADS1262 delta-sigma ADC.

Features
  • >50:000 noise-free count weigh-scale solution Operating temperature range: -40 ᵒC to +125 ᵒC Less than 1 μV total error across temperature range ADC Supply and Bridge Excitation Voltage: 5V Bridge Output: 0 V to 10 mV Firmware provides ADS1262 example code This robust circuit reference design includes theory: complete error analysis: component selection: simulation: PCB design: example code: and measured data that correlates with the theory and simulation.
Applications
  • Spectrometer
  • CT & PET scanner
  • Weigh scale
  • X-ray systems
  • Mobile robot motor control
Product Categories
  • Data converters

Parts

Part Number Name Companion Part
MSP430F5529 MSP430F5529 Buy Datasheet
TS5A21366 TS5A21366 Buy Datasheet

Bill Of Materials

Download the bill of materials for TIPD188 Download

Schematic

Quickly understand overall system functionality.

Download the schematic for TIPD188

Test Data

Get results faster with test and simulation data that's been verified.

Download the test file for TIPD188

Other Documents

Title Updated Type Size (KB)
TIPD188 BOM 20 Jul 2015 PDF 193
TIPD188 Schematic 20 Jul 2015 PDF 176